public readonly struct Statusword(ushort value)
{
public ushort Value { get; init; } = value;
public bool ReadyToSwitchOn => (Value & 0x0001) != 0;
public bool SwitchedOn => (Value & 0x0002) != 0;
public bool OperationEnabled => (Value & 0x0004) != 0;
public bool Fault => (Value & 0x0008) != 0;
public bool VoltageEnabled => (Value & 0x0010) != 0;
public bool QuickStop => (Value & 0x0020) != 0;
public bool SwitchOnDisabled => (Value & 0x0040) != 0;
public bool Warning => (Value & 0x0080) != 0;
public bool TargetReached => (Value & 0x0400) != 0;
/// <summary>
/// CiA402 Statusword bit 12: Homing attained (homing completed successfully)
/// </summary>
public bool HomingAttained => (Value & 0x1000) != 0;
/// <summary>
/// CiA402 Statusword bit 13: Homing error (homing failed)
/// </summary>
public bool HomingError => (Value & 0x2000) != 0;
public DriveState GetState()
{
if (!ReadyToSwitchOn && !SwitchedOn && !OperationEnabled && !Fault && SwitchOnDisabled)
return DriveState.SwitchOnDisabled;
if (!ReadyToSwitchOn && !SwitchedOn && !OperationEnabled && !Fault && !SwitchOnDisabled)
return DriveState.NotReadyToSwitchOn;
if (ReadyToSwitchOn && !SwitchedOn && !OperationEnabled && !Fault)
return DriveState.ReadyToSwitchOn;
if (ReadyToSwitchOn && SwitchedOn && !OperationEnabled && !Fault)
return DriveState.SwitchedOn;
if (ReadyToSwitchOn && SwitchedOn && OperationEnabled && !Fault)
return DriveState.OperationEnabled;
if (!ReadyToSwitchOn && !SwitchedOn && !OperationEnabled && Fault)
return DriveState.Fault;
return DriveState.Unknown;
}
public override string ToString() => $"0x{Value:X4} ({GetState()})";
public static implicit operator ushort(Statusword sw) => sw.Value;
public static implicit operator Statusword(ushort value) => new(value);
}