Every driver must normalize its device's native scale into ROS REP-103
right-handed CCW (0 = front, + = left). Spells out the three stackable
device quirks to absorb — shifted 0° reference, clockwise scale,
upside-down mounting — and warns that a CW scale decoded as CCW mirrors
the world invisibly on single-lidar devices: verify handedness against
the real room, not just against motion.