namespace RobotNet10.RobotApp.Drivers.Battery.Varta;
|
||||
|
||||
/// <summary>
|
||||
/// Varta CAN client — đọc dữ liệu pin qua CANopen PDO.
|
||||
/// Dùng SocketCAN transport có sẵn trong RobotNet10.CANOpen.
|
||||
/// Protocol (CAN 11-bit):
|
||||
/// 0x19B -> Voltage, Current
|
||||
/// 0x281 -> FetTemp, CellTemp, ChargeReqVoltage, ChargeReqCurrent
|
||||
/// 0x381 -> NominalCapacity, FullCapacity, RemainingCapacity, SOC
|
||||
/// 0x481/0x581 -> Info, Warn, Error, ChargeCtrl
|
||||
/// </summary>
|
||||
public sealed class VartaCanClient : IDisposable
|
||||
{
|
||||
private readonly ILogger _logger;
|
||||
private readonly ICanOpenManager _canOpenManager;
|
||||
private readonly string _canInterface;
|
||||
private readonly int _readTimeoutMs;
|
||||
private readonly Lock _stateLock = new();
|
||||
private readonly ConcurrentQueue<CanFrameReceivedEventArgs> _rxQueue = new();
|
||||
private readonly SemaphoreSlim _rxSignal = new(0);
|
||||
private ICanBus? _bus;
|
||||
private bool _disposed;
|
||||
private bool _isFaulted;
|
||||
|
||||
public bool IsFaulted
|
||||
{
|
||||
get
|
||||
{
|
||||
lock (_stateLock)
|
||||
{
|
||||
return _isFaulted;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
public VartaCanClient(ILogger logger, ICanOpenManager canOpenManager, string canInterface, int readTimeoutMs = 200)
|
||||
{
|
||||
_logger = logger;
|
||||
_canOpenManager = canOpenManager;
|
||||
_canInterface = string.IsNullOrWhiteSpace(canInterface) ? "can0" : canInterface;
|
||||
_readTimeoutMs = Math.Max(10, readTimeoutMs);
|
||||
|
||||
OpenBus();
|
||||
}
|
||||
|
||||
|
||||
private void OpenBus()
|
||||
{
|
||||
lock (_stateLock)
|
||||
{
|
||||
_isFaulted = false;
|
||||
}
|
||||
|
||||
try
|
||||
{
|
||||
// Xóa bus cũ khỏi cache của CanOpenManager trước khi tạo lại,
|
||||
// tránh GetOrCreateCanBusAsync trả về bus đã chết do caching.
|
||||
_logger.LogInformation("[VartaCanClient] Removing old CAN bus from cache for {Iface}", _canInterface);
|
||||
_canOpenManager.RemoveCanBusAsync(_canInterface).GetAwaiter().GetResult();
|
||||
|
||||
var bus = _canOpenManager.GetOrCreateCanBusAsync(_canInterface).GetAwaiter().GetResult();
|
||||
_logger.LogInformation("[VartaCanClient] CAN bus recreated for {Iface}, IsConnected={IsConnected}", _canInterface, bus.IsConnected);
|
||||
|
||||
lock (_stateLock)
|
||||
{
|
||||
if (_bus != null)
|
||||
{
|
||||
_bus.FrameReceived -= OnFrameReceived;
|
||||
}
|
||||
|
||||
_bus = bus;
|
||||
_bus.FrameReceived += OnFrameReceived;
|
||||
}
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
lock (_stateLock)
|
||||
{
|
||||
_isFaulted = true;
|
||||
}
|
||||
// _logger.LogError(ex, "[VartaCanClient] Không thể mở SocketCAN trên interface {Iface}", _canInterface);
|
||||
}
|
||||
}
|
||||
|
||||
public void ForceReconnect()
|
||||
{
|
||||
if (_disposed)
|
||||
{
|
||||
return;
|
||||
}
|
||||
|
||||
_logger.LogInformation("[VartaCanClient] ForceReconnect start {Iface}", _canInterface);
|
||||
|
||||
lock (_stateLock)
|
||||
{
|
||||
try
|
||||
{
|
||||
if (_bus != null)
|
||||
{
|
||||
_bus.FrameReceived -= OnFrameReceived;
|
||||
}
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
_logger.LogError(ex, "[VartaCanClient] No data in {Iface}", _canInterface);
|
||||
}
|
||||
|
||||
while (_rxQueue.TryDequeue(out _)) { }
|
||||
while (_rxSignal.Wait(0)) { }
|
||||
}
|
||||
|
||||
OpenBus();
|
||||
_logger.LogInformation("[VartaCanClient] ForceReconnect Finished, IsFaulted={IsFaulted}", _isFaulted);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Đọc frame mới nhất từ queue receive và decode theo protocol Varta.
|
||||
/// Drain toàn bộ queue, chỉ giữ frame mới nhất cho mỗi CAN ID để tránh trễ dữ liệu.
|
||||
/// </summary>
|
||||
public Dictionary<string, double>? ReadResponse(int maxFrames = 30)
|
||||
{
|
||||
if (_disposed || IsFaulted || _bus == null || !_bus.IsConnected)
|
||||
{
|
||||
return null;
|
||||
}
|
||||
|
||||
// Nếu queue rỗng, chờ frame mới đến
|
||||
if (_rxQueue.IsEmpty)
|
||||
{
|
||||
try
|
||||
{
|
||||
if (!_rxSignal.Wait(_readTimeoutMs))
|
||||
{
|
||||
return null;
|
||||
ForceReconnect();
|
||||
}
|
||||
}
|
||||
catch
|
||||
{
|
||||
return null;
|
||||
}
|
||||
}
|
||||
|
||||
// Drain toàn bộ queue, chỉ giữ frame mới nhất cho mỗi CAN ID
|
||||
var latestFrames = new Dictionary<uint, CanFrameReceivedEventArgs>();
|
||||
while (_rxQueue.TryDequeue(out var frame))
|
||||
{
|
||||
latestFrames[frame.CanId] = frame;
|
||||
// Drain semaphore để khớp với số frame bị loại bỏ
|
||||
_rxSignal.Wait(0);
|
||||
}
|
||||
|
||||
if (latestFrames.Count == 0)
|
||||
{
|
||||
return null;
|
||||
}
|
||||
|
||||
var result = new Dictionary<string, double>(StringComparer.OrdinalIgnoreCase);
|
||||
foreach (var frame in latestFrames.Values)
|
||||
{
|
||||
DecodeFrame(frame, result);
|
||||
}
|
||||
|
||||
return result.Count == 0 ? null : result;
|
||||
}
|
||||
|
||||
private void OnFrameReceived(object? sender, CanFrameReceivedEventArgs e)
|
||||
{
|
||||
if (_disposed)
|
||||
{
|
||||
return;
|
||||
}
|
||||
|
||||
_rxQueue.Enqueue(e);
|
||||
try
|
||||
{
|
||||
_rxSignal.Release();
|
||||
}
|
||||
catch (SemaphoreFullException)
|
||||
{
|
||||
}
|
||||
}
|
||||
|
||||
private static void DecodeFrame(CanFrameReceivedEventArgs frame, Dictionary<string, double> result)
|
||||
{
|
||||
// uint canId = frame.CanId & 0x7FFu;
|
||||
var d = frame.Data;
|
||||
|
||||
if (d == null)
|
||||
{
|
||||
return;
|
||||
}
|
||||
|
||||
// var canBase = canId & 0x780u;
|
||||
|
||||
switch (frame.CanId)
|
||||
{
|
||||
case 0x181: // TPDO1: 0x180 + NodeId
|
||||
{
|
||||
uint voltage = BitConverter.ToUInt32(d, 0);
|
||||
int current = BitConverter.ToInt32(d, 4);
|
||||
double volts = voltage / 1000.0;
|
||||
double amps = current / 1000.0;
|
||||
result["Voltage"] = Math.Round(volts, 1, MidpointRounding.ToZero);
|
||||
result["Current"] = Math.Round(amps, 1, MidpointRounding.ToZero);
|
||||
// Console.WriteLine($"[VartaCanClient] Received TPDO1: Voltage={volts} V, Current={amps} A, Timestamps: {DateTime.Now:HH:mm:ss.fff} s");
|
||||
break;
|
||||
}
|
||||
|
||||
case 0x281: // TPDO2: 0x280 + NodeId
|
||||
result["FetTemp"] = BitConverter.ToInt16(d, 0) / 10.0;
|
||||
result["CellTemp"] = BitConverter.ToInt16(d, 2) / 10.0;
|
||||
result["ChargeReqVoltage"] = BitConverter.ToUInt16(d, 4) / 1000.0;
|
||||
result["ChargeReqCurrent"] = BitConverter.ToUInt16(d, 6) / 1000.0;
|
||||
// Console.WriteLine($"[VartaCanClient] Received TPDO2: FetTemp={result["FetTemp"]} °C, CellTemp={result["CellTemp"]} °C, ChargeReqVoltage={result["ChargeReqVoltage"]} V, ChargeReqCurrent={result["ChargeReqCurrent"]} A");
|
||||
break;
|
||||
|
||||
case 0x381: // TPDO3: 0x380 + NodeId
|
||||
{
|
||||
var nominal = BitConverter.ToUInt16(d, 0);
|
||||
var full = BitConverter.ToUInt16(d, 2);
|
||||
var remaining = BitConverter.ToUInt16(d, 4);
|
||||
result["NominalCapacityMah"] = nominal;
|
||||
result["FullCapacityMah"] = full;
|
||||
result["RemainingCapacityMah"] = remaining;
|
||||
result["SOC"] = full == 0 ? 0 : remaining * 100.0 / full;
|
||||
result["SOH"] = nominal == 0 ? 0 : full * 100.0 / nominal;
|
||||
// Console.WriteLine($"[VartaCanClient] Received TPDO3: Nominal={nominal} mAh, Full={full} mAh, Remaining={remaining} mAh, SOC={result["SOC"]} %, SOH={result["SOH"]} %");
|
||||
break;
|
||||
}
|
||||
|
||||
case 0x481: // TPDO4: 0x480 + NodeId
|
||||
|
||||
case 0x581: // SDO response: 0x580 + NodeId (some firmware puts status words here)
|
||||
result["Info"] = BitConverter.ToUInt16(d, 0);
|
||||
result["Warn"] = BitConverter.ToUInt16(d, 2);
|
||||
result["Error"] = BitConverter.ToUInt16(d, 4);
|
||||
result["ChargeCtrl"] = BitConverter.ToUInt16(d, 6);
|
||||
// Console.WriteLine($"[VartaCanClient] Received TPDO4/SDO: Info={result["Info"]}, Warn={result["Warn"]}, Error={result["Error"]}, ChargeCtrl={result["ChargeCtrl"]}");
|
||||
break;
|
||||
|
||||
case 0x264:
|
||||
result["ChargeControl"] = d[0]; // byte 0: uint8
|
||||
result["SOC"] = d[1]; // byte 1: uint8, %
|
||||
// byte 2: không sử dụng
|
||||
result["ChargeVoltageRequest"] = BitConverter.ToUInt16(d, 3) / 256.0; // bytes 3-4: uint16, 1/256 V
|
||||
result["ChargeCurrentRequest"] = BitConverter.ToUInt16(d, 5) / 16.0; // bytes 5-6: uint16, 1/16 A
|
||||
result["BatteryStatus"] = d[7]; // byte 7: uint8
|
||||
// Console.WriteLine($"[VartaCanClient] Received 0x264: ChargeControl={result["ChargeControl"]}, SOC={result["SOC"]} %, ChargeVoltageRequest={result["ChargeVoltageRequest"]:F4} V, ChargeCurrentRequest={result["ChargeCurrentRequest"]:F4} A, BatteryStatus={result["BatteryStatus"]}");
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
public void Dispose()
|
||||
{
|
||||
lock (_stateLock)
|
||||
{
|
||||
if (_disposed)
|
||||
{
|
||||
return;
|
||||
}
|
||||
_disposed = true;
|
||||
}
|
||||
|
||||
try
|
||||
{
|
||||
_bus?.FrameReceived -= OnFrameReceived;
|
||||
}
|
||||
catch
|
||||
{
|
||||
}
|
||||
finally
|
||||
{
|
||||
_rxSignal.Dispose();
|
||||